FB27 FLT GLB : High-Bay-Storage - control cabinet faults

 

 

 

Netzwerk 1: 1_FLT_X0 Res.

#"1_FAULT_00_15".%X0 := FALSE;

 

 

 

Netzwerk 2: 1_FLT_X1 E00 G120C_X MCB

#"1_FAULT_00_15".%X2 := NOT "E00 G120C_Y MCB";

 

 

 

Netzwerk 3: 1_FLT_X2 E00 G120C_Y MCB

#"1_FAULT_00_15".%X2 := NOT "E00 G120C_Y MCB";

 

 

 

Netzwerk 4: 1_FLT_X3 E00 G120C_Z MCB

#"1_FAULT_00_15".%X4 := NOT "E00 M302 MCB";

 

 

 

Netzwerk 5: 1_FLT_X4 M302 MCB

#"1_FAULT_00_15".%X4 := NOT "E00 M302 MCB";

 

 

 

Netzwerk 6: 1_FLT_X5 M303 MCB

#"1_FAULT_00_15".%X5 := NOT "E00 M303 MCB";

 

 

 

Netzwerk 7: 1_FLT_X6 M304 MCB

#"1_FAULT_00_15".%X5 := NOT "E00 M304 MCB";

 

 

 

Netzwerk 8: 1_FLT_X7 M305 MCB

#"1_FAULT_00_15".%X7 := NOT "E00 M305 MCB";

 

 

 

Netzwerk 9: 1_WRN_X0 Emergency stop P03

#"1_WARN_00_15".%X0 := NOT "E00 26S1 Estop";

 

 

 

Netzwerk 10: 1_WRN_X1 Emergency stop P02

#"1_WARN_00_15".%X1 := NOT "E00 27S5 Estop";

 

 

 

Netzwerk 11: 1_WRN_X2 Emergency stop cabinet

#"1_WARN_00_15".%X2 := NOT "E00 EStp ok";

 

 

 

Netzwerk 12: Complete module fault message

"ModulDa".GLB.STS."1_ModuleFLT_00_31" := DW#16#FFFFFFFF AND (SHL_DWORD(IN := #"1_FAULT_00_15", N := 16) OR #"2_FAULT_00_15");

"ModulDa".GLB.STS."2_ModuleFLT_00_31" := DW#16#FFFFFFFF AND (SHL_DWORD(IN := #"3_FAULT_00_15", N := 16) OR #"4_FAULT_00_15");

#FLT_MODULE := 0 <> ("ModulDa".GLB.STS."1_ModuleFLT_00_31" OR "ModulDa".GLB.STS."2_ModuleFLT_00_31");

 

 