FB50 MAIN P03 : P03 main automatic program (VMA)

[hit  <- on your browser to return]

 

 

 

Netzwerk 1: P03 Initialisation

IF "M03 Init" OR NOT "M00 OB1 FirstCycle" THEN

    #STEP_BITS := 0;

    IF "M03 Init" THEN

        "M03 MD50" := "M03 MD54" := 0;

        "M03 HomPosRun" := TRUE;

        "DatOfMod".P03.CrntModule := 103;

    END_IF;

END_IF;

 

 

 

Netzwerk 2: P03 SET execute home position

IF "M03 HomPosRun" AND #SET.S.step0 THEN

    #SET.S.steps := TRUE;

ELSIF NOT "M03 HomPosRun" OR "HMI KEY".SYS.GLB.F8_Stop OR "HMI KEY".P03.GLB.F8_Stop THEN

    #SET.S.steps := "M03 HomPosRun" := FALSE;

END_IF;

#SET.S.steph := "M03 FLT ModuleStpSR";

#SET();

 

 

 

Netzwerk 3: P03 SEQ1 start, stop, hold

#SEQ1.S.steph := NOT "M00 AutoCmpltMa run" AND "M03 SEQ1 Start";

#SEQ1.S.steps := NOT "M03 HomPosRun" AND "M03 SEQ1 Start";

 

IF "M00 CmpltMaOFF Imp" THEN

    #SEQ1.S.stepin := FALSE;

END_IF;

#SEQ1();

 

 

 

Netzwerk 4: P03 FLT faults monitoring

#FLT(FLT_MODULE := "M03 FLT ModuleIS");

 

 

 

Netzwerk 5: P03 STEP.SEQ1_Start

IF "M00 CmpltMaRun Imp" AND ("M00 AutoCmpltMa run" XOR "M00 InchCmpltMa run") THEN

    #STEP.SEQ1_Start := TRUE;

    RETURN;

ELSIF #STEP.SEQ1_Start THEN

    IF NOT ("M03 HomPosRun" OR "M03 SEQ1 Active") THEN

        "M03 SEQ1 Start" := TRUE;

    ELSIF "M03 SEQ1 Active" THEN

        #MoDa.RunTimeCntr_seq1 := 0;

        #STEP_BITS := 0;

        #STEP.SEQ1_Running := TRUE;

    END_IF;

END_IF;

 

 

 

Netzwerk 6: P03 STEP.SEQ1_Running

IF #STEP.SEQ1_Running THEN

    IF "M03 SEQ1 Done" THEN

        "M03 SEQ1 Start" := FALSE;

        #STEP_BITS := 0;

        #STEP.SEQ1_Done := TRUE;

        RETURN;

    END_IF;

END_IF;

 

 

 

Netzwerk 7: P03 STEP.Done

IF #STEP.SEQ1_Done THEN

    "M03 SEQ1 Done" := FALSE;

    #STEP_BITS := 0;

    #STEP.SEQ1_Write := TRUE;

    // Save actual data   

    "DatOfMod".P03.STS.RunTimeCntr_seq1 := #MoDa.RunTimeCntr_seq1;

    "DatOfMod".P03.STS.WPC_ok := "M03 SEQ1 DoWP1" AND "M03 SEQ1 WP1 DnOK";

    "DatOfMod".P03.STS.CrntWP_ok := "M03 SEQ1 WP1 DnOK" AND NOT "M03 SEQ1 WP1 DnNOK";

   

    "DatOfMod".P03.TrgtModule := 104;

    // If necessary, changing drive direction to module 103   

    IF NOT "DatOfMod".P03.STS.CrntWP_ok THEN

        "DatOfMod".P03.TrgtModule := 105;

    END_IF;

    "DatOfPLC".P03 := "DatOfMod".P03; // BLKMOV

END_IF;

 

 

 

Netzwerk 8: P03 STEP.Write

IF #STEP.SEQ1_Write THEN

    "M03 SEQ1 WP1 DnOK" := "M03 SEQ1 DoWP1" := FALSE;

    "M03 TCP/IP Wrt start" := TRUE;

   

    IF "M03 TCP/IP Wrt done" THEN

        "M03 TCP/IP Wrt start" := "M03 TCP/IP Wrt done" := FALSE;

        #STEP_BITS := 0;

        RETURN;

    END_IF;

END_IF;

 

 

 

Netzwerk 9: P03 Run-Time

"M03 Enabled" := "M00 AutoCmpltMa run" AND NOT "M03 FLT ModuleStpSR";

IF #STEP.SEQ1_Running THEN

    IF "M00 Imp 10Hz" AND "M03 Enabled" THEN

        #MoDa.RunTimeCntr_seq1 := #MoDa.RunTimeCntr_seq1 + 1;

    END_IF;

ELSE

    IF NOT "M03 Active" AND "M00 AutoCmpltMa run" THEN

        #STEP.SEQ1_Start := TRUE;

    END_IF;

END_IF;

 

 

 

Netzwerk 10: P03 SEQ1 active

"M03 Active" :=

#STEP.SEQ1_Start AND "M03 SEQ1 Active"

OR #STEP.SEQ1_Running

OR #STEP.SEQ1_Done

OR #STEP.SEQ1_Write;

 

 

 

Netzwerk 11: P03 Assing signal  

IF "M02 FLT ModuleIS" THEN

    "M03 FLT ModuleStpSR" := true;

END_IF;

IF "M03 FLT ModuleStpSR" AND NOT "M03 FLT ModuleStpACK" THEN

    IF "M00 FLT CmpltMaACK Imp" THEN

        "M03 FLT ModuleStpACK" := true;

    END_IF;

ELSIF NOT "M03 FLT ModuleIS" AND "M03 FLT ModuleStpACK" THEN

    "M03 FLT ModuleStpSR" := "M03 FLT ModuleStpACK" := FALSE;

END_IF;