FB37 FLT GLB : Pending fault analysis

 

 

 

Network 1: External acknowledgment, if needed

IF #FLT_MODULE AND "DI MAIN GLB".M00.FLT_EntirePlant_ACK_Imp THEN

 ;

END_IF;

 

 

 

Network 2: 1_F00_X0 DC24V NOK

#"1_FAULT_00_15".%X0 := NOT "E00 DC24V ok";

 

 

 

Network 3: F00_X1 AC400V NOK

#"1_FAULT_00_15".%X1 := NOT "E00 AC400V ok";

 

 

 

Network 4: 1_F00_X2 S210A1 MCB

#"1_FAULT_00_15".%X2 := NOT "E00 S210A1 MCB";

 

 

 

Network 5: 1_F00_X3 S210A2 MCB

#"1_FAULT_00_15".%X3 := NOT "E00 S210A2 MCB";

 

 

 

Network 6: 1_F00_X4 S210A3 MCB

#"1_FAULT_00_15".%X4 := NOT "E00 S210A3 MCB";

 

 

 

Network 7: 1_F00_X5 S200A4 MCB

#"1_FAULT_00_15".%X5 := NOT "E00 S200A4 MCB";

 

 

 

Network 8: 1_F00_X6 G120 MCB

#"1_FAULT_00_15".%X6 := NOT "E00 G120 MCB";

 

 

 

Network 9: 1_F00_X7 ROBOT CB

#"1_FAULT_00_15".%X7 := NOT "E00 ROBOT CB";

 

 

 

Network 10: 1_F00_X8 AirPressure NOK

#"1_FAULT_00_15".%X8 := NOT "E00 AirPressure OK";

 

 

 

Network 11: 1_F00_X9 CAMERA CB

#"1_FAULT_00_15".%X9 := NOT "E00 CAMERA CB";

 

 

 

Network 12: 1_F00_X10 M201 MCB

#"1_FAULT_00_15".%X10 := NOT "E00 M201 MCB";

 

 

 

Network 13: 1_F00_X11 M202 MCB

#"1_FAULT_00_15".%X11 := NOT "E00 M202 MCB";

 

 

 

Network 14: 1_F00_X12 M203 MCB

#"1_FAULT_00_15".%X12 := NOT "E00 M203 MCB";

 

 

 

Network 15: 1_W00_X0 Estop Cabinet NOK

#"1_WARN_00_15".%X0 := NOT "E00 Estop Cab";

 

 

 

Network 16: 1_W00_X1 Estop OnSeite NOK

#"1_WARN_00_15".%X1 := NOT "E00 Estop OnSite";

 

 

 

Network 17: Pending faults analysis

"ModuleData".P00.STS."1_Modu

leFLT_00_31" := DW#16#FFFFFFFF AND (SHL_WORD(IN := #"1_FAULT_00_15", N := 16) OR #"2_FAULT_00_15");

#FLT_MODULE := 0 <> "ModuleData".P00.STS."1_ModuleFLT_00_31";