FB37 FLT GLB : Pending fault analysis |
|
|
|
|
|
Network 1: External acknowledgment, if needed IF #FLT_MODULE AND "DI MAIN GLB".M00.FLT_EntirePlant_ACK_Imp THEN ; END_IF; |
|
|
|
|
|
Network 2: 1_F00_X0 DC24V NOK #"1_FAULT_00_15".%X0 := NOT "E00 DC24V ok"; |
|
|
|
|
|
Network 3: F00_X1 AC400V NOK #"1_FAULT_00_15".%X1 := NOT "E00 AC400V ok"; |
|
|
|
|
|
Network 4: 1_F00_X2 S210A1 MCB #"1_FAULT_00_15".%X2 := NOT "E00 S210A1 MCB"; |
|
|
|
|
|
Network 5: 1_F00_X3 S210A2 MCB #"1_FAULT_00_15".%X3 := NOT "E00 S210A2 MCB"; |
|
|
|
|
|
Network 6: 1_F00_X4 S210A3 MCB #"1_FAULT_00_15".%X4 := NOT "E00 S210A3 MCB"; |
|
|
|
|
|
Network 7: 1_F00_X5 S200A4 MCB #"1_FAULT_00_15".%X5 := NOT "E00 S200A4 MCB"; |
|
|
|
|
|
Network 8: 1_F00_X6 G120 MCB #"1_FAULT_00_15".%X6 := NOT "E00 G120 MCB"; |
|
|
|
|
|
Network 9: 1_F00_X7 ROBOT CB #"1_FAULT_00_15".%X7 := NOT "E00 ROBOT CB"; |
|
|
|
|
|
Network 10: 1_F00_X8 AirPressure NOK #"1_FAULT_00_15".%X8 := NOT "E00 AirPressure OK"; |
|
|
|
|
|
Network 11: 1_F00_X9 CAMERA CB #"1_FAULT_00_15".%X9 := NOT "E00 CAMERA CB"; |
|
|
|
|
|
Network 12: 1_F00_X10 M201 MCB #"1_FAULT_00_15".%X10 := NOT "E00 M201 MCB"; |
|
|
|
|
|
Network 13: 1_F00_X11 M202 MCB #"1_FAULT_00_15".%X11 := NOT "E00 M202 MCB"; |
|
|
|
|
|
Network 14: 1_F00_X12 M203 MCB #"1_FAULT_00_15".%X12 := NOT "E00 M203 MCB"; |
|
|
|
|
|
Network 15: 1_W00_X0 Estop Cabinet NOK #"1_WARN_00_15".%X0 := NOT "E00 Estop Cab"; |
|
|
|
|
|
Network 16: 1_W00_X1 Estop OnSeite NOK #"1_WARN_00_15".%X1 := NOT "E00 Estop OnSite"; |
|
|
|
|
|
Network 17: Pending faults analysis "ModuleData".P00.STS."1_Modu leFLT_00_31" := DW#16#FFFFFFFF AND (SHL_WORD(IN := #"1_FAULT_00_15", N := 16) OR #"2_FAULT_00_15"); #FLT_MODULE := 0 <> "ModuleData".P00.STS."1_ModuleFLT_00_31"; |
|