FB20 MAIN GLB : Operation mode

 

 

 

Network 1 - Network 15 // know-how protected

 

 

 

Network 16: LogIn mc@cea2020

IF "HMI SYS".Login.Operator_0.ID = "HMI SYS".Login.Admin.ID THEN

     "HMI SYS".Login.Operator_0.Initials := "HMI SYS".Login.Admin.Initials;

     #M00.LogInID_CEA := #M00.LogInID_OK := TRUE;

ELSIF "HMI SYS".Login.Operator_0.ID = "HMI SYS".Login.Operator_1.ID THEN

     "HMI SYS".Login.Operator_0.Initials := "HMI SYS".Login.Operator_1.Initials;

     #M00.LogInID_OK := TRUE;

     #M00.LogInID_CEA := FALSE;

ELSIF "HMI SYS".Login.Operator_0.ID = "HMI SYS".Login.Operator_2.ID THEN

     "HMI SYS".Login.Operator_0.Initials := "HMI SYS".Login.Operator_2.Initials;

     #M00.LogInID_OK := TRUE;

     #M00.LogInID_CEA := FALSE;

ELSE

     #M00.LogInID_CEA := #M00.LogInID_OK := FALSE;

END_IF;

IF NOT #M00.LogInID_OK THEN

     "HMI SYS".Login.Operator_0.Initials := '';

END_IF;

#M00.TON_Login(IN := #M00.LogInID_CEA,

               PT := #M00.TON_Login.PT);

IF #M00.TON_Login.Q THEN

     "HMI SYS".Login.Operator_0.ID := '';

END_IF;